Strafer Engineering PLLC · New York

New York's engineer of record for critical power and electrification.

Sealed DOB electrical plan review filings, capacity studies and power system studies, for the contractors and suppliers who build the work and the owners who pay for it.

New firm. 25 years in critical power.

Set up a master agreement Contractors and suppliers
Send a project Owners and managers

NY PE No. 092566 · NYSED COA No. 0024417 · No equipment sales, no commissions

Illustration of a critical power one-line diagram Two utility services feed a main-tie-main switchboard. Three generators parallel on a switchgear bus. Two automatic transfer switches pick up from either source and feed two UPS systems that serve the critical load. An inset shows coordinated time-current curves. Illustrative only. UTILITY A UTILITY B G1 G2 G3 MAIN – TIE – MAIN PARALLELING SWITCHGEAR ATS-1 ATS-2 UPS-A UPS-B CRITICAL LOAD TIME–CURRENT
Quick check

Does your NYC project need a PE?

Answer a few questions. The logic follows NYC Electrical Code §110.2(B) and 1 RCNY §4000-01. It's a guide, not a code determination. Nothing you enter leaves this page.

Services

Four things we do, in New York only.

Engineer of Record

DOB electrical plan review filings for contractors and equipment suppliers. One master agreement, a task order per job, a fixed fee per filing.

How it works

Electrification & Capacity

Heat pumps, EV charging, electric water heating. Load studies, Con Edison load letters and service upgrade design.

Capacity studies

Power System Studies

Short-circuit, protective device coordination and arc flash (IEEE 1584-2018 / NFPA 70E). Selective coordination reports for DOB.

Studies

Local Law 97

Annual report certification by a PE. Help for late filers. An electrical readiness plan for the 2030 limits.

LL97
Why us

Built for the people who build it.


Gear-level depth

25 years across the critical power chain: switchgear, generators, automatic and static transfer switches, UPS, and power control systems.


Independent

No equipment sales. No commissions. The design answers to the code and to you, not to a product line.


Built for repeat work

One master agreement. A task order per job. Standard turnaround: 11 business days from a complete package, 5 for a resubmittal.

Sample deliverable

See the method before you sign.

A sample filing package on a fictional building: the one-line, the kVA calculation, a coordination excerpt and a capacity summary.

View the sample
Sample one-line diagram excerpt for a fictional building, including paralleled generators and an N+1 multi-module UPS system
Sample — fictional building, not a client project.
Credentials

Justin M. Strafer, PE, MBA

Principal, Strafer Engineering PLLC

25 years across the critical power chain: switchgear, generators, automatic and static transfer switches, UPS, and power control systems.

  • LicenseNew York Professional Engineer No. 092566
  • FirmNYSED Certificate of Authorization No. 0024417 (Strafer Engineering PLLC)
  • EducationBS Electrical Engineering, NJIT · Executive MBA (Finance), Rutgers
  • PatentsNamed inventor on U.S. patents
  • SectorsData centers, healthcare, water/wastewater

Have a job going to DOB?

Send the one-line and the equipment list. We'll tell you what the filing needs and quote a fixed fee.

jstrafer@straferengineering.com
Site visits in all five boroughs and across New York State.