Local Law 97

LL97 report certification, from a PE.

Every covered building files an annual emissions report, certified by a registered design professional. We review the data, certify the report, and help you plan for the stricter limits that start in 2030.

The rules

What LL97 asks of owners

  • LL97 covers most buildings over 25,000 gross square feet, plus groups of buildings on one tax lot over 50,000 gross square feet.
  • Emissions limits started in 2024. Stricter limits take effect in 2030.
  • Article 320 buildings file an annual emissions report by May 1, certified by a registered design professional.
  • In 2026, reports were due by May 1 and no later than June 30, with an extension to August 29 available on request by June 30. No professional attestation is needed to request an extension.
  • For Article 321 buildings using the performance-based pathway, only a PE or RA may submit the attestation.

Late or missed report?

The penalty for failing to file is the building's gross floor area × $0.50 for each month the report is late, within the 12 months after May 1 (Admin. Code §28-320.3.7). DOB's guidance says a failure-to-file notice can be resolved with zero penalty by submitting an extension request and the report within 60 days of the notice.

Guide: late LL97 filing and penalties →
Services

What we do

Annual report certification

We review the benchmarking and energy data, the building's characteristics and the calculation, and certify the report as the registered design professional.

Late-filer help

We prioritize getting a missing report filed and correct, so the monthly penalty stops growing.

2030 electrical readiness

Electrification is the usual path to the 2030 limits. We check whether the electrical service can carry it and what an upgrade involves.

Capacity studies
Benchmarking and energy-services firms

Need a PE to certify your clients' reports?

Accepting inquiries from benchmarking and energy-services firms. You prepare the data; we review and certify as the registered design professional, under our responsible charge.

Start a conversation

What "certify" means here

We certify only what we have reviewed. That means access to the inputs behind the report, not just the summary, and time to resolve questions before the deadline.

Guide: what the RDP does on an LL97 report →

Report due, or already late?

Send the building's address and BBL. We'll tell you what we need to certify the report and quote a fixed fee.

jstrafer@straferengineering.com
Site visits in all five boroughs and across New York State.